Size: 48 x 96mm.
Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: voltage output (for driving SSR).
Temperature controller with single alarm output.
SV and PV can be displayed at the same time.
Multiple temperature range allows setting the optimum temperature range .
The protection function can prevent the error in operation 70068-1005 DAL10(B). Programmable Controllers Join the Series!
Program up to 256 segments and take advantage of the high cost performance,
of the new LCD that improves both the field of view and contrast
70068-1005 DAL10(B)
Set up to 8 programmed patterns with up to 32 segments (steps) each.
High-resolution display with 5 digits/0 70068-1005 DAL10(B). 01°C display.
High-speed sampling cycle of 60 ms .
High Accuracy.
Thermocouple/Pt input: ±0.1% of PV,
Analog input: ±0.1% FS,
Universal inputs on all models (thermocouple, PT, or analog,
input) to handle various sensors with one Controller. Models,
also available with Remote SP.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/RESET, and alarms) and the PV or SV 70068-1005 DAL10(B).
Flexible contact outputs with logic operations (AND, OR, and,
delays) set from the Support Software (CX-Thermo version,
4.3). Program settings can be managed.
An infrared ports enables communications from the front panel.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Model available with position-proportional control. E32-A09H type: special beam type; liquid level detection,
Specialty: heat resistant 150 C 3,
Bending radius (mm): R35.
Fiber element for meeting diversified needsTime specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily beecause operation time,
is indicated from the start of operation 70068-1005 DAL10(B).
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions 70068-1005 DAL10(B). Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
70068-1005 DAL10(B) Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70068-1005 DAL10(B)&select=5