Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function 70156-2827 MS46SR-14-1045-Q1-1.
Event input points: -
70156-2827 MS46SR-14-1045-Q1-1
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance 70156-2827 MS46SR-14-1045-Q1-1.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation 70156-2827 MS46SR-14-1045-Q1-1.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc . , can be a key operation. Optional laser sensor to provide the best laser sensor for different scenes at the most suitable price.
Make the workpiece color, material, surface state is different, can also be a compact body to achieve stability detection.
[stability] [rest assured].
OMRON original HSDR-CMOS (Seed and Dynamic Range High).
Dynamic range 500 thousand times.
Adjusting the CMOS shutter time according to the workpiece.
Can adjust the power of light, to achieve the best of the diffusion of light intake.
The background is used as a benchmark to detect all parts of the benchmark.
Can not be affected by the workpiece surface state and the stability of the impact of the tilt, even if the workpiece changes, there is no need to set. Control power supply voltage: 48 VDC.
Input: DC or AC (selectable), Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using ccurrennt converter 70156-2827 MS46SR-14-1045-Q1-1.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection 70156-2827 MS46SR-14-1045-Q1-1.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).