Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: - .
Event input points: -.
Transfer output: - 70156-4005 MS46LR-20-1215-Q2-1.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products
70156-4005 MS46LR-20-1215-Q2-1
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 70156-4005 MS46LR-20-1215-Q2-1. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms .
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultAppearance: Rectangular (M16-A) 70156-4005 MS46LR-20-1215-Q2-1.
Lighting: LED without Voltage Reduction Unit, 12 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC / wire type.
Polarity: there.
Shape: shield, M30.
Detection range: 10mm.
Action mode: NC. Size: 48 * 48mm, terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display functiion, tto see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV 70156-4005 MS46LR-20-1215-Q2-1.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm fflexible contact output 70156-4005 MS46LR-20-1215-Q2-1.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
70156-4005 MS46LR-20-1215-Q2-1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70156-4005 MS46LR-20-1215-Q2-1&select=5