Differential output.
Axis of control: 1.
Maximum output pulse: pulse/s 4M.
Location data: 600 data / axis.
Max link distance: 10m.
Start is also simple.
Digital oscilloscope function.
Data collection and data collection in a simple motion controller that is synchronized with the control period.
Waveform display, you can improve the efficiency of the start A1SX81.
The use of steps in accordance with the auxiliary function can be
A1SX81
Can be set by different uses of the probe, easy to view the data set.
Can be on the word 16CH, bit 16CH data sampling.
Among them, the word 8CH, bit 8CH data can be displayed in real time.
Monitoring and testing function
Through a wealth of monitoring and testing functions, you can simply start and action check A1SX81.
Can only choose the necessary items from the rich monitoring information and monitor the display.
Through the test function, do not have to control procedures can also be implemented to confirm the basic action. 8.4 inches.
Applicable models: GT27, GT25, GT23. Voltage and current output module.
Number of channels: 2 channels.
Occupied station number: 16 point pattern occupies 4 stations A1SX81.
Screw terminal table type.
Input output points can be saved by using different input and output points based on the final channel that allows the conversion.
Special flat cable directly mounted to the module. Output points: 32 points.
Voltage: DC5/12/24V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output (type sink).
Response time: 10ms.
8 points / a common end.
50 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selecttion,
Under the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A1SX81.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation A1SX81.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.