Relay output: 32.
Rated current and voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end, 8 point 1 Public end.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AY13.Motor series: low inertia, medium capacity.
Rated output power: 6.0kw.
Rated speed: 1000rpm.
With the brake: without .
Shaft end: straight shaft AC50TB-E.
The rotor of the servo motor is a permanent magnet, which is controlled by the U/V/W,
The rotor rotates under the action of the magnetic field, and the encoder feedback signal of the motor is given to the driver,
According to the feedback value and the target value, the driver adjusts the rotation angle of the rotor
AC50TB-E
Accuracy of the servo motor depends on the accuracy of the encoder (number of lines) AC50TB-E. Output points: 64 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process AC50TB-E. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read .
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selectioon,
Under the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AC50TB-E.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AC50TB-E.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
AC50TB-E Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AC50TB-E&select=5