LK166
Home >> Price >> MITSUBISHI >> AD35ID2
Brand sort

MITSUBISHI AD35ID2

Country: JAPAN
Name: ID system module
Model: AD35ID2
Price: 0
MITSUBISHI AD35ID2
Connecting cable for handheld GOT and PLC.
Cable length: 1.5 meters.
Application: RS-422 connection (FX series). Analog input points: 4 points (thermocouple, PT, constant voltage input).
Output points: transistor output 4 points, 4 point CT input.
Weight: 0.4KG.
Temperature sensor with 4CH input control output,
Double position control, standard PID control,
Heating and cooling PID control, cascade control AD35ID2
By using the combination of the analog output module,
PID control of voltage or current can be realized.
New with cascade control. Through the master / slave station of the 2 controllers,
According to the temperature change caused by external disturbance, the temperature can be adjusted quickly AD35ID2.
Can connect FX3GA/FX3G, FX3GE, FX3U series.
When connecting to FX3UC or FX3GC, you need FX2NC-CNV-IF or FX3UC-IPS-5V. Multi axis positioning controller.
Optical data communication line.
Program capacity: Max 60K step.
Input / output points: 1920 points.
When the switch is off, the diode does not emit light, and the transistor is not on the way. Internal circuit input signal AD35ID2.
It is through the input interface circuit to the external switch signal into PLC internal can accept the digital signal .
Photoelectric three levels: in the light of the light signal conduction, the degree of light signal and the intensity of the light signal.
The output signal has a linear relationship with the input signal in the linear operating region of the photoelectric coupler.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The photoelectric coupler is composed of two luminous two extreme tubess and a photoelectric transisstor AD35ID2.
Light emitting diode two: the input of a photo coupler and the change of electrical signal,
The light signal is generated by the light emitting diode, which is the same as the input signal.
The working process of the input interface circuit: whhen the switch is closed, the diode light,
The transistor is then guided to the internal circuit and input signal under the irradiation of the light AD35ID2.
AD35ID2 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=AD35ID2&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
ID system module
AD35ID2
MITSUBISHI ID system module AD35ID2
Program 2 channel connection, AnCPU/QnAC
MITSUBISHI
Reader module
A1SD32ID2
MITSUBISHI Reader module A1SD32ID2
AnS, QnAS us connection, the reader to
MITSUBISHI
ID interface module
QD35ID2
MITSUBISHI ID interface module QD35ID2
Connect to read and write 2Ch. ID system
MITSUBISHI
Reader module
A1SD35ID2
MITSUBISHI Reader module A1SD35ID2
Reader writer 2 channel connection, AnSC