Program capacity: 124 K step.
Input / output points: 4096 points.
Number of input and output elements: 8192.
Processing speed: 0.034 s.
Program memory capacity: 496 KB.
Support USB and RS232.
CPU module expansion standard RAM (max 8MB).
Can be used with the SD memory card at the same time.
Continuous access file register .
Ultra high speed processing, production time is shortened, better performance
AJ65FBTA4-16D
As applications become larger and more complex, it is necessary to shorten the system operation cycle time.
The operation period can be shortened by the super high basic operation speed 1.9ns.
In addition to achieve in the past with the control of single-chip high-speed control,
The system performance can be improved by reducing the total scan time,
To prevent any possible performance bias AJ65FBTA4-16D. 10Mbps Max., master / local station, support Ver.2 CC-Link.
CC-Link is a bus (RS-485) - type open field network which can control and information processing at the same time.
Can be in the CC-Link and high-speed transmission of ON/OFF information from the station equipment, such as bit data, analog information, such as digital data AJ65FBTA4-16D.
Connect all kinds of field equipment through CC-Link.
Can connect all kinds of support CC-Link field equipment, according to various control requirements to build the corresponding system.
Use remote device network mode, up to 64 remote equipment such as analog devices, etc.. Output points: 64 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With the surge absorber (optocoupler diode).
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Unnder the premise of meeeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AJ65FBTA4-16D.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AJ65FBTA4-16D.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
AJ65FBTA4-16D Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AJ65FBTA4-16D&select=5