Motor series: flat type, medium and small power.
Rated output power: 2.0kw.
Rated speed: 2000r/min.
Whether to bring the brakes: with.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: flat type design makes this more suitable for installation in space.
Application examples: robot, food manufacturing machinery .
High resolution encoder 131072p/rev (17 bit) AX10Y22C.
The encoder with high resolution ensures excellent performance and stability at low speed
AX10Y22C
All motor dimensions are the same as before and all are compatible with the wiring. Servo motor series: low inertia, medium power.
Rated output: 3.0kw.
Rated speed: 2000r/min.
Electromagnetic brake: No AX10Y22C.
Shaft end specification: Standard (straight axis) .
Features: low inertia is widely used in general machinery.
IP level: IP65.
Application example:
1, roller type feeding equipment.
2, loading / unloading equipment.
3, high frequency transmission system.
Abundant motor product line can optimize the performance of the machine.
Has a rich motor product line including a rotary servo motor, linear servo motor and direct drive motor AX10Y22C. Input and output points: 480 points.
Program capacity: 7K step.
Basic command processing speed: 4.4 ~ 5.6us.
Power supply: input AC100 ~ 120/200 ~ 240V/ output 2A DC24V, 0.5A DC5V.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normallly open contact is closed,
Provide load current and voltage AX10Y22C.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnnected from the load AX10Y22C.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.