Memory format: EEPROM.
Number of steps: up to 4000 steps can be used.
Battery support: do not.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the peripheral device. The connector is converted to a spring clip terminal row.Servo motor series: low inertia, small capacity .
Rated output: 0 AX81C. 75kw.
Rated speed: 3000r/min.
Electromagnetic brake: there.
Oil seal: have
AX81C
Corresponding servo amplifier: MR-JE-10B/MR-JE-10A.
Support position control, speed control, torque control, push and press control.
Position control can use linear, arc interpolation controller, fixed size feed control, target position change and other rich functions AX81C.
The position control and torque control are realized by switching control mode .
The gain adjustment of servo can be simply performed by the advanced one key tuning function.
At the same time, it is also able to suppress the low frequency vibration of the manipulator by the advanced vibration suppression control II,
Shorten the time to complete the positioning, so as to achieve the production of the rhythm of the shortening AX81C. Input type: DC input, positive common end.
Input points: 8 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 500KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is thee frequency of the inverter volltage proportional to the change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotoor AX81C AX81C.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.