Total input and output points: 32 points.
Input points: 16 points.
Output points: 16 points.
Output type: relay output.
Power supply voltage: AC100-240V.
Input signal voltage: DC24V.
8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions .
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules
AY60E
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable AY60E.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register AY60E.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your program. Drive unit.
MITSUBISHI universal AC servo amplifier MELSERVO-J4 series.
Rated output: 30kw.
Interface: universal type.
Power supply: three phase AC200V.
Special specifications: full closed control 4 wire / support mechanical end encoder ABZ phase input / support positioning mode.
Support position control, speed control, torque control.
Position conttrol to follow the position insstructions AY60E.
When the control is inserted, the position control is performed.
Speed control follows the speed command to control the speed within a certain range.
Torque control to follow the torque command to control the stable torque.
Function of swwitching amplitude AY60E. The increase in the process of switching and stopping,
And in the operation of the use of the switching signal, switching growth.
AY60E Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=AY60E&select=5