LK166
Home >> Price >> MITSUBISHI >> FR-CB03
Brand sort

MITSUBISHI FR-CB03

Country: JAPAN
Name: Parameter unit connection cable
Model: FR-CB03
Price: 0
MITSUBISHI FR-CB03
"MITSUBISHI general purpose AC servo amplifier MELSERVO-J2-Super series.
Rated output: 5.0kw.
Built in positioning function.
Voltage: 3 phase AC200VAC or single phase AC230V.
Compatible with "MR-J2S- CP-S084" - servo amplifier and interface unit "MR-J2S-TO1" positioning by CC-Link
Simply setting the point table .
AC servo can be used as the driving source of the field network FR-CB03.
Using servo amplifier built-in positioning function, position data and speed data, you can set the CC-Link FR-CB03
Start, stop and display can also be transmitted through the CC-Link.
Serial communication reduces wiring.
AC servo distributed control system can be easily constructed. "Analog input channel number: 16CH FR-CB03.
accuracy
Ambient temperature of 25 plus or minus 5 degrees C: plus or minus 0 . 1%.
Ambient temperature 0 ~ 55 degrees C:-.
Temperature coefficient: positive and negative 35ppm/.
Common
Conversion speed: 10ms.
Insulation between channels: isolation transformer insulation.
Absolute maximum input: positive and negative 15V, 30mA.
External wiring connection: 40 pin connector two FR-CB03.
Voltage input
The analog input voltage: DC - 10 - 10V .
Digital output value: 32000 ~ 32000.
Current input
Analog input current: DC0 ~ 20mA.
Digital output value: 0 ~ 32000.
Execute event driven program through alarm output
Strengthen the implementation of the interrupt function according to the alarm output flag, easy to carry out preventive maintenance.
The measured value and the change rate of the analog input signal exceed the upper and lower limits of the set,
Regardless of the procedure of the scan time, can be executed interrupt handling, quickly respond to abnormal conditions.
Analog input module for the external analog signal into the interface of the programmable controller.
Can choose the channel between the insulation, voltage input, current input, voltage / currennt mixed input, thermocouple input, temperature resistance (RTD) input for a variety of purposes, such as modules FR-CB03.
Filter high frequency interference.
Analog input module has been equipped with a first order lag filter.
The analog input signal with high frequency interferencee ccomponent can be obtained by using the first order lag filter FR-CB03.
Parameters can be set through the filter time constant, no program can be easy to use.
FR-CB03 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=FR-CB03&select=5


...more relevant model market price >>>>
Related products
MITSUBISHI
3 phase 400V converter
FR-F740P-15K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-15K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 200V converter
FR-F720-7.5K
MITSUBISHI 3 phase 200V converter FR-F720-7.5K
MITSUBISHI inverter FR-F720 series. Volt
MITSUBISHI
3 phase 400V converter
FR-E740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-E740-0.4K-CHT
MITSUBISHI inverter FR-E740 series. Volt