Max input / output points: 60 points.
Power supply voltage: 12-24VDC.
Input points: 36 points.
Output points: 24 points.
Output type: relay.
Power consumption (W): 20.
Weight (kg):0.8.
Size (WxHxD) mm:175x90x75.
Terminal row type standard machine with extended input output
Can also be less of a system with analog or communication, etc . .
CPU, power supply, input and output integration FR-CV-H55K.
Display module or function expansion board can be less installed
FR-CV-H55K
In addition, you can also reduce the input output or special module.
Built in 8000 step EPROM memory.
No battery. Maintenance free.
Overseas oriented products meet all kinds of international standards.
FX1N series is a very powerful micro PLC, can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board FR-CV-H55K.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect.
A PLC unit can output 2 100KHz pulses at the same time,
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute position readout, absolute or relative drive, and special pulse output control FR-CV-H55K. D-STN color / monochrome LCD man-machine interface to replace the backlight.
Applicable model: A970GOT-SB_/LB_. 2 slots.
No need to install power.
For QnA/A series.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling FR-CV-H55K.
Cenntralized output mode .
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation FR-CV-H55K.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FR-CV-H55K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FR-CV-H55K&select=5