Enter points: 64 points.
Voltage: DC12/24V.
Current: 3/7mA.
Response time: 10ms.
32 points / a common end.
Cathode common.
40 pin connector.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation .
Read only memory FX0N-232ADP. Manufacturers use, content can not be changed, power does not disappear
FX0N-232ADP
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference FX0N-232ADP. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read FX0N-232ADP.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 0.4KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions.
High level driving performance.
Unique sensorless vector control mode,
A widee variety of mechanical eequipment can be operated at high precision in the super low speed region without the need of the encoder FX0N-232ADP.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequuenncy converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc FX0N-232ADP. ) and torque control.
FX0N-232ADP Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX0N-232ADP&select=5