Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 8A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor
FX0N-24MR-D
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc FX0N-24MR-D. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian FX0N-24MR-D.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process .
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption: 25W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x86.
Built in CPU, power supply, input and output. By using a rich variety of functional extension boards and special adapters,
Can achieve high precision control.
Based on the function of FX2N has been greatly strengthened and enhanced.
High speed operation.
Basic instructions: 0.065 s/ instruction.
Application instruction: 0.642 s/ instruction.
Large capacity memory.
Built in program memory 64000 steps.
Flash memory cartridge with program transfer function.
Authentication。
Corresponding EN and UL/cUL authentication.
Faster and more efficient. Support high speed control and network communication, and have the function of data recording.
High speed, large capacity, multi-function high-end machine.
FX3U supports high speed processing, CC-Link communication, network communication, analog control and advanced positioning system.
Connected to the CC-Link, including the remote I/O, the maximum input and output control points up to 3384 points,
Can corresponnd to a variety of field needs, the use of its scalability and flexibility to expand the scope of application of the control system FX0N-24MR-D.
Third generation high function micro programmable controller.
High speed, high efficiency, high performance, large caapacity, and new features FX0N-24MR-D.
Built in high speed processing and positioning.
Control points: maximum 256 points.
Use CC-Link remote I/O for 384 points.
FX0N-24MR-D Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX0N-24MR-D&select=5