Type: sensor connector (e-CON).
Output form: transistor output, leakage type.
Output points: 16 points.
Rated input voltage / current: DC12/24V (0.5A).
External connection: 3 wire.
By using the output ON number of times, it is convenient to confirm the total number of ON of each output point.
High speed input and output control of a single module can be realized by using first order logic function
FX3S-14MT/DSS
IE CC-Link field network remote equipment station. According to the equipment, more easily distributed input and output devices.
Can be connected to the expansion module, more convenient to expand the input and output points.
Support synchronous communication (using with simple motion control module) FX3S-14MT/DSS.
According to the simple motion control module of the network (Master) control cycle of the implementation of the control cycle and its synchronization,
Implementation of multiple simultaneous action from the station. Servo motor series: ultra low inertia, low power.
Rated output: 0.05kw.
Rated speed: 3000r/min.
Electromagnetic brake: with.
Shaft end specification: Standard (straight axis) FX3S-14MT/DSS.
Features: ultra low inertia is very suitable for high frequency operation.
IP level: IP65.
Application example:
1, insert machine.
2, assembly machinery.
Rotary servo motor.
Numerous motor series and wide motor power range can be used to meet different applications.
The protection level of the HF-KP/HF-MP/HC-LP/HC-RP/HC-UP servo motor to improve the environmental safety is IP65 (except the shaft part). A3VTS with additional floor.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of cenntralized sampling FX3S-14MT/DSS.
Cenntralized output mode .
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation FX3S-14MT/DSS.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
FX3S-14MT/DSS Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX3S-14MT/DSS&select=5