Cable length: 0.2 meters.
QCPU/L02SCPU (-P) RS-422 cable (GT01-C / R4-25P, GT10-C / R4-25P, GT21-C / R4-25P5).
L6ADP-R2 RS-422 (GT01-C cable - R4-25P GT10-C - R4-25P, GT21-C -, R4-25P5).
[MINI-DIN 6 pin D-sub 25 pin].
Applicable models: GT27, GT25, GT23, GT21. Available network: 10BASE2.
Max / total distance: 185/925m .
A1SJ71E71 is a compact Ethernet interface module,
Used to hang PLC series ANS to ethernet
FX3U-4AD
There are two kinds of hanging network modules: A1SJ71E71-B2-S3 and A1SJ71E71-B5-S3 respectively corresponding to 10BASE2 and 10BASE5,
So that the vast majority of installed cable can continue to use. Input type: DC input, negative public end.
Input points: 16 points FX3U-4AD.
Enter the response time: 1 . 5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector FX3U-4AD.
When installing the module can choose to use the DIN guide rail or screw mounting .
3 wire sensor input. Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: relay.
Power consumption: 50VA.
Weight (kg):1.
Size (WxHxD) mm:220x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Paassword protection, using a eight digit password to protect your program FX3U-4AD.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time FX3U-4AD.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
FX3U-4AD Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FX3U-4AD&select=5