Input and output points: 40 points.
Power supply: DC24V.
Input points: 24 points.
Output points: 16 points.
Output form: transistor output (source).
Power consumption: 25W.
Weight: 0.7KG.
Outline dimension: 130x90x86mm.
FX3GE on the performance of the FX3GA increased analog input / output and Ethernet communication and other built-in features GT01-C10R4-8P.
Applicable to a wide variety of applications.
Basic unit: 24/40 point
GT01-C10R4-8P
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost PLC.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
A versatile PLC.
Built in CPU, power supply, input and output, analog input and output, Ethernet port, can be used immediately after the purchase GT01-C10R4-8P.
High speed operation.
Basic instructions: 0.21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function. MITSUBISHI general purpose AC servo amplifier MR-J2 series.
Rated output: 0 GT01-C10R4-8P. 75kw.
Interface: SSCNET type.
Voltage: single phase AC200V .
MR-J2 series server system has the ability to carry out a higher precision control,
Using high performance CPU, greatly improve the responsiveness of the product,
Speed loop frequency response increased to 550HZ.
Various series of servo motors are suitable for different control requirements,
The encoder on the servo motor supports ABS mode,
As long as the servo amplifier on the other plus batteries,
Can form an absolute position system. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequenncy converter to realizze the power consumption reduction of standby time GT01-C10R4-8P.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the correspondinng signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation GT01-C10R4-8P.
Can reduce the power consumption in the stop.
GT01-C10R4-8P Operation manual / Instructions / Catalog download link: