Motor series: flat type, medium and small power.
Rated output power: 3.5kw.
Rated speed: 2000r/min.
Whether to take the brake: No.
Shaft end: Standard (straight).
Protection level: IP65 (IP67).
Features: flat type design makes this more suitable for installation in space.
Application examples: robot, food manufacturing machinery .
High resolution encoder 131072p/rev (17 bit) GT1020-LBDW.
The encoder with high resolution ensures excellent performance and stability at low speed
GT1020-LBDW
All motor dimensions are the same as before and all are compatible with the wiring. Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side GT1020-LBDW.
Positive pole sharing.
Output points: 24 points .
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control GT1020-LBDW.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these sstandard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal GT1020-LBDW.
So the standard telecommunication number, the conversiionn between the number of operations to use a variety of computing GT1020-LBDW.
This requires the resolution of the analog unit and the standard electrical signal.
GT1020-LBDW Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=GT1020-LBDW&select=5