1 axis servo amplifier.
MITSUBISHI general AC servo amplifier MELSERVO-J4 series.
Rated output: 11.0kw.
Interface: SSCNET III /H.
Power supply: three phase AC200V.
Special specification: support for CC-LinkIE.Field network motion control.
Servo amplifier supporting IE Field CC-Link network.
Ethernet based open network, support for motion control GT16-90PSCB.
Improve mechanical properties by high performance motor
GT16-90PSCB
By improving the resolution and processing speed of the encoder,
The rotating servo motor has higher precision and better performance of rotation.
Only open a key type of adjustment function, can be carried out including mechanical resonance filter, high end seismic control II, low pass filter servo gain adjustment GT16-90PSCB.
Easily start advanced seismic function, it can maximize the mechanical properties.
It can automatically adjust the required response settings automatically. Drive: MR-H_ACN series built-in positioning function.
Rated output: 15KW.
In servo drive speed closed loop,
Rotor speed measurement accuracy is very important to improve the dynamic and static characteristics of the speed control loop GT16-90PSCB.
In order to seek the balance between measurement precision and system cost, incremental photoelectric encoder is generally used as the speed measuring sensor,
The corresponding method is M/T velocity measurement.
Although the M/T measurement method has a certain measurement accuracy and a wide range of measurement,
But this method has its inherent defects,
Mainly includes: the measurement period must be detected at least one complete encoder pulse, limiting the minimum detectable speed.
2 control system for speed control of the timer switch is difficult to maintain synchronization,
Can not guarantee the accuracy of measurement in the situation where the speed change is larger.
Therefore, it is difficult to improve the speed tracking and control performance of servo drive by using the traditional speed loop design method. 3C-2V/5C-2V coaxial cable.
Double circuit.
MELSECNET (II) (Master / local station).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the systemm GT16-90PSCB.
MITSUBISHI PLC initiallization procedure . After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program arre:: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc GT16-90PSCB. .
GT16-90PSCB Operation manual / Instructions / Catalog download link: