Cable length: 0.6m.
For the connection between QCPU and GOT.
For connection between two GOT.
Applicable models: GT16, GT15, GT11, GT27, GT25. MITSUBISHI general purpose AC servo amplifier MR-J2 series.
Rated output: 3.5kw.
Interface: general purpose interface.
Voltage: three phase AC200V.
MITSUBISHI servo system in the MITSUBISHI servo amplifier is widely used,
It can not only be used in the high precision position control and speed control of the working machinery and general industrial machinery,
Can also be used in the field of speed control and tension control
HC-MFS/KFS13G2 (1/20)
By installing a personal computer with a servo setting software, the parameters setting, trial run, state display, and gain adjustment are performed HC-MFS/KFS13G2 (1/20).
MITSUBISHI servo system MR-J2S column is developed on the basis of the servo MR-J2 series with a higher performance and more features of the MITSUBISHI servo system,
The control modes are position control, speed control and torque control, as well as the switching control mode among them. Motor series: low inertia, medium capacity HC-MFS/KFS13G2 (1/20).
Using a serial absolute / incremental encoder .
Rated output power: 1.0kw.
Rated speed: 3000rpm.
With the brake: without.
Shaft end: straight shaft.
Performance comparison of servo motor and stepping motor.
Stepper motor as an open-loop control system, and modern digital control technology has the essential link.
In the current domestic digital control system, stepping motor is widely used.
With the emergence of digital AC servo system, AC servo motor is more and more used in digital control system.
In order to adapt to the development trend of digital control, most of the motion control system adopts stepping motor or full digital AC servo motor as executive motor.
Although they are similar in control mode (pulse train and directional signal), there are great differences in performance and application.
The use performance of the two are compared.The most appropriate temperature regulation control (PID control) is possible,
In order to control the PID does not need to specify a special command.
In addition, according to the automatic regulation function,
The automatic setting of PID number is possible.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the exteernal output siignal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse oof the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on HC-MFS/KFS13G2 (1/20) HC-MFS/KFS13G2 (1/20).
This phenomenon is called the I/O delay time effect.