DC input points: 8 points.
Input voltage and current: 7mA, DC24V.
Response time: 10ms.
8 point /1 a public side.
Positive / negative sharing.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered .
It can avoid the control logic confusion caused by illegal operations HC-RFS103BG2 1/9.
MITSUBISHI PLC initialization procedure
HC-RFS103BG2 1/9 After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc HC-RFS103BG2 1/9. .
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program HC-RFS103BG2 1/9.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation . Applicable models: FX3GC, FX3UC.
Input voltage: DC24V.
Weight: 0.15kg.
FX3UC-1PS-5V is when the FX3GC, FX3UC series of extended power supply for the additional power supply.
Has the capacity of 1A DC5V, but also can be used as a conversion adapter for FX2N/FX3U to extend the device. MITSUBISHI inverter FR-E720 series.
Voltage level: 3 phase 200V.
Frequency converter capacity: 0.4KW.
In order to ensure the reliability of production, all production machinery in the design of power with drive, there is a certain amount of surplus.
When the motor can not run under full load, in addition to meet the requirements of power driven,
The surplus torque increases the active power consumption, resulting in the waste of electric energy.
SSpeed control methodd of fan and pump equipment traditional by regulating the entrance or exit of the baffle, valve opening to regulate air flow and water flow
, the input power is large, and a large amount of energy consumption in the baffle, the valve in the processs off closure HC-RFS103BG2 1/9 HC-RFS103BG2 1/9.
When using variable frequency control, if the flow rate is reduced, the speed of the pump or fan can be reduced to meet the requirements.