Input / output type: transistor output (source).
Output points: 8 points.
DC5V internal consumption current: 75mA.
DC24V internal consumption current: 75mA.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256 .
Expansion module: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points
HF-SE202K Length: 55mm.
Function: connect GM-FX.
Corresponding models: FX2N-10GM, FX2N-20GM. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 2.2KW HF-SE202K.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) .
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical HF-SE202K.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load. Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 5.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording.
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file sttored on the SD memory cardd can be sent to the FTP server HF-SE202K.
Because the record server can handle multiple files, it can reduce the task of management and maintenance.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do noot have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution HF-SE202K.
HF-SE202K Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=HF-SE202K&select=5