MITSUBISHI motor universal AC servo amplifier MELSERVO-J3 series.
Rated output: 0.1kw.
Interface type: SSCNET type III fiber communication.
Special features: integrated driver security.
Power specification: single phase AC100V.
STO function as a security feature is added to the SSCNET III fiber communication type servo amplifier .
By using the STO function, the electromagnetic contactor used in the past to prevent the motor from accidentally starting is no longer needed
MR-E70A
SS1 functions can be realized by using the MR-J3-D05 security logic unit.
MR-J3-BS uses a full closed loop control system.
Compatibility with MR-J3-B.
MR-J3-BS installation, wiring and connectors are the same as the MR-J3-B, so do not change the existing connection will be easy to MR-J3-B
Change to MR-J3-BS MR-E70A.
Security functions are connected to the CN8 interface through an external security circuit to increase the MR-J3-BS driver security.
Compatible full closed loop control system.
MR-J3-BS has a full closed loop control system version. MES interface module.
Need MX MESInterface software and CF card MR-E70A.
Easily connect production equipment and information system .
Through the excellent database sharing function, greatly reduce the cost of information.
By direct connection, the connection process of the enterprise system database (such as MES) is simplified.
Module configuration is simple, without any programming.
The data can be monitored in the module side, when a user defined trigger condition occurs,
Will be read in the form of SQL text and send the specified data to the MES.
The network load can be reduced compared with the previous scheme which is based on the gateway PC to obtain / monitor the data.
Receive information from the MES, perform pre stored SQL tasks.
In addition, the production instructions from the MES are also received,
The production information can be downloaded from the database, and the modification of the formula information can be conveniently carried out. Output channel number: 4ch.
Output voltage: DC - 10 ~ 10V.
Output current: DC0 ~ 20mA.
Conversion speed: 20 s/ch.
Resolution: 1/20000.
Status of connected devices by means of alarm monitoring.
Alarm output function
Process alarm.
When the digital value is in the range of preset, the output alarm.
Change rate alarm.
The output value of the output value of the digital output is too large (greater than the rate of change of the alarm limit) or too small (less than the rate of change), the output alarm.
Achieve stability measurement
Inter channel isolation
Isolation between the channels, can prevent the connection of sensors in the channel between the cross talk, so as to achieve staable measurement MR-E70A.
High speed,, smooth continuous analog output .
Waveform output function
Equipped with the industry''s first waveform output function.
The pre prepared waveform data can be imported into the analog output module, and the function of the analog output is simulattedd according to the set conversion period MR-E70A.
It is not affected by the sequential scan time, and it can realize the high speed and smooth analog output.
MR-E70A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-E70A&select=5