32: terminal line adapter 0.3mm2 (AGW22).1 axis servo amplifier.
MITSUBISHI general AC servo amplifier MELSERVO-J4 series.
Rated output: 5.0kw.
Interface: SSCNET III /H.
Power supply: three phase AC400V.
0.6kW and 1kW above the servo amplifier.
Servo amplifier supporting SSCNET III /H.
Complete synchronization system capable of using high speed serial optical communication MR-J2HBUS05M.
Can be combined with the servo system controller to maximize the performance of the servo system
MR-J2HBUS05M
Improve mechanical properties by high performance motor.
By improving the resolution and processing speed of the encoder,
The rotating servo motor has higher precision and better performance of rotation MR-J2HBUS05M.
Only open a key type of adjustment function, can be carried out including mechanical resonance filter, high end seismic control II, low pass filter servo gain adjustment .
Easily start advanced seismic function, it can maximize the mechanical properties.
It can automatically adjust the required response settings automatically. Superior high efficiency IPM motor.
Output power: 55kw MR-J2HBUS05M.
Rated speed: 1500r/min.
Voltage level: 400V .
IPM motor MM-EFS series can not be used to run the power frequency power.
The total wiring length of the IPM motor shall not exceed 100m.
1 inverters can not connect multiple IPM motors at the same time. Input and output points: 1024 points.
Input / output data points: 1024 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
AnNCPU command processing time and ACPU compare to 10-20% high speed processing.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 22 words MR-J2HBUS05M. Data operation instructions for 2~4 .
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ulltra small PLC using this structure MR-J2HBUS05M.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
MR-J2HBUS05M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MR-J2HBUS05M&select=5