"Maximum control axis: 2 axis.
Connection mode with servo amplifier: SSCNET III /H connection type.
The maximum distance between the drive units: 100m.
Operation cycle: 0.88ms.
Interpolation function: linear interpolation (maximum 4 axis), 2 axis arc interpolation.
Color signal: 2 points.
Color detecting set: 4 set .
Even the long distance wiring can be flexible MR-J2S-20CP-S084.
The use of fiber optic cable, with high speed, high performance, high reliability of the servo system controller network
MR-J2S-20CP-S084
In addition to the traditional positioning control, but also to support speed / torque control and synchronous control.
Use simple movement module setup tool",
Can easily perform positioning settings, monitoring and debugging, etc MR-J2S-20CP-S084. .
In addition, the data can be collected and displayed synchronously with the motion controller.
SSCNET III /H connection to save the wiring, the maximum distance between the station up to 100m,
Absolute position system can be easily supported.
The upper limit limit switch, the lower limit switch and the near point block signal are input by the servo amplifier,
Thus greatly reducing wiring MR-J2S-20CP-S084.
In addition to positioning control and speed control, but also to perform synchronization control, cam control, torque control, touch pressure control, etc..
Positioning module (QD75MH) of the project and the sequence of the previous model is highly compatible with the old model,
The project can be easily applied to the simple motion module (QD77MS). "MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 22KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, thee starting current iis 6~7 times of the rated current, therefore, the impact on the mechanical and electrical MR-J2S-20CP-S084.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rrated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load MR-J2S-20CP-S084.