Cable length: 1.0m.
Amplifier CC-Link interface unit cable.
For MR-J2S-11KA (4) MR-J2S-22KA to (4).
Amplifier and CC-Link interface unit using 0.5 m (1.64 ft) or shorter cables. Motor series: medium inertia, medium capacity.
Using a serial absolute / incremental encoder.
Rated output power: 3.5kw.
Rated speed: 3000rpm .
With the brake: without Q06HCPU-A.
Shaft end: straight shaft.
When the AC servo motor has no control voltage, only the pulsating magnetic field generated by the excitation winding is generated in the stator, and the rotor is still not moving
Q06HCPU-A
When the control voltage is controlled, a rotating magnetic field is generated in the stator, and the rotor rotates in the direction of the rotating magnetic field,
In the case of constant load, the speed of the motor varies with the size of the control voltage,
When the phase of the control voltage is reversed, the servo motor will reverse Q06HCPU-A. Motor power adapter kit; HF-SP51; 81; 102; 152; 52;
1024; 524; 1524
HF-JP53; 73; 103; 153; 203; 534;
734; 1034; 1534; 2034;
5034; 3534Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V Q06HCPU-A.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: DC12V/24V.
OFF leakage current: 0.1mA.
Output response time: 2ms.
Output type: transistor output.
8 point /1 a public end, 4 point /1 a public end.
36 point terminal station.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switchiing signal, the fault signaal transmission device, brake signal and fan fault signal Q06HCPU-A.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points Q06HCPU-A.
Q06HCPU-A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Q06HCPU-A&select=5