10BASE-T.
For Q mode.
When communicating in the PLC network of MITSUBISHI,
There is no sense of difference and discontinuity in the network,
Can carry on the remote monitoring, modification, debugging and other work of data communication and program,
Without taking into account the level and type of network .
MELSECNET/H and CC-Link use the way of loop communication,
Periodically automatically send and receive messages,
Does not require specialized data communication procedures,
Simple parameters can be set
Q172DEX
MELSECNET/H and CC-Link are used to transmit and receive the broadcast mode,
This can be done on the network data sharing.
For the use of Ethernet, MELSECNET/H, CC-Link network,
Can set the network parameters and various functions, simple and convenient in the Developer GX software screen Q172DEX. Input: 4 channels.
Platinum resistance (Pt100; JPt100).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module Q172DEX.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regulating module has the function of preventing overheating and preventing over cooling .
According to the control object device, select the standard control (heating or cooling) or the heating and cooling control (heating and cooling) mode.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing tthe operation cost Q172DEX.
Heating ffunction at the same time .
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PIID constant can be adjusted automatically in the control process Q172DEX.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Q172DEX Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Q172DEX&select=5