230.4kbps Max., RS-232 2 channel.
When using the serial communication module, it is only necessary to select from the communication protocol library of engineering software,
Can carry out data communication support MODBUS general agreement.
2 channels are supported 230.4kbps, communication can fully play the performance of the matching equipment QD62E. Input points: 32 points.
Input voltage: DC24V.
Enter the public side of the way: 32 points / public
QD62E
Output form: transistor output (drain).
Output points: 32 points.
Rated output voltage: DC12 ~ 24V.
Max load current: 0.1A/1 point.
Protection function: have
Output common way: 32 point / common.
Input / output occupied points: 32 points (I/O distribution: input and output mixed 32 points) QD62E.
External wiring connection: 40 pin connector two.
1, the switch quantity acquisition and switch control and RS-485 bus are isolated from each other, and isolated from the whole system.
2, the power supply line has anti reverse connect function, once the wrong power line,
Will automatically cut off the power to protect the entire module is not damaged QD62E.
With over-voltage protection function, when the voltage is too high, automatic disconnection,
Protecting the entire module is not damaged .
3, RS-485 interface with 600W lightning protection and surge protection function, with 3000V photoelectric isolation.
4, the use of Modbus protocol, good general, can be very convenient and other systems,
Customers can also according to their own personal needs, custom related agreements, convenient and flexible.
5, communication lines using RS-485 bus, support for multiple modules in parallel use,
Easy to expand the system, good scalability. Max input / output points: 48 points.
Supply voltage: 100 - 240VAC.
Input points: 24 points.
Output points: 24 points.
Output type: Transistor (sinktype).
Power consumption: 50VA.
Weight (kg):0.85.
Size (WxHxD) mm:182x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and daata via modem communications
Paassword protection, using a eight digit password to protect your program QD62E.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off tthe continuous scan time QD62E.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).