Servo motor series: low inertia, medium / high power.
Rated output: 1.5kw.
Rated speed: 3000r/min.
Electromagnetic brake: with.
Shaft end specification: Standard (straight axis).
Voltage: 400V level.
Features: low inertia for high speed / acceleration and deceleration operation occasions.
IP level: IP67 .
Application example:
1, food processing machinery QJ71LP21GE.
2, printing machine.
3, injection molding machine (11KW, 15KW)
QJ71LP21GE
4, large press machine (11KW, 15KW).
The protection level of the HF-SP/HF-JP series servo motor is IP67 (except the shaft part).
Low inertia of the power servo motor (0.5kW ~ 9kW), the maximum speed: 6000r/min (rated speed: 3000r/min),
Suitable for high frequency positioning and acceleration / deceleration operations, especially for food processing machines and printing machines QJ71LP21GE.
Low inertia, high power, no cooling fan servo motor (11kW and 15kW), maximum speed: 3000r/min (rated speed: 1500r/min).
The motor structure is more compact due to the adoption of the non cooling fan design, and the connection is reduced by using the power source connector QJ71LP21GE.
(compared with the HF-LP series servo motor with the same power, the volume is reduced by about 46%, and the weight is reduced by about 34%,
Suitable for high frequency positioning and acceleration / deceleration operations, especially for injection molding machines and large presses .
HF-JP703 (4) /903 (4) maximum speed: 5000r/min. Three remote components can be connected to the CC-LINK system.
Remote I/O: refers to the field components that require only ON/OFF control,
Such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: the field components that require processing of register data,
For example analog I/O and counter, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication.
Intelligent remote: this type of element refers to the actions that allow the master station or other station to access,
To collect data and control the local PLC station,
GOTS and programmer interface unit are of this type.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequence number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next round of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work.
PLC is the use of " sequential scanning, and constantly circulating " way to work.
That is, in the operation of CPU, PLC according to the user according to the control requirements of the coexistence of the user in the memory of the program,
According to the instruction sequennce number (or address number) for periodic cyclic scan, such as no jump instruction,
From the first instruction to the user program execution sequence one by one, until the end of the program,
And then return to the first command, start the next rrounnd of the new scan, in the process of each scan,
Also complete the sampling of the input signal and the output status of the refresh and other work QJ71LP21GE QJ71LP21GE.