LK166
Home >> Price >> MITSUBISHI >> QS0J65BTB2-12DT
Brand sort

MITSUBISHI QS0J65BTB2-12DT

Country: JAPAN
Name: Safety CC-Link system remote I/O module
Price: 0
MITSUBISHI QS0J65BTB2-12DT
Cable length: 3m.
For the connection between Q/LCPU and GOT.
For connection between two GOT.
Applicable models: GT10, GT21. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end QS0J65BTB2-12DT.
Output response time: 12ms.
Output type: relay output QS0J65BTB2-12DT
8 point /1 a public end, 3 point /1 a public end.
Independent contact.
36 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points QS0J65BTB2-12DT.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian QS0J65BTB2-12DT.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process .
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching siggnal, the fault signaal transmission device, brake signal and fan fault signal QS0J65BTB2-12DT.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee ssystem controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points QS0J65BTB2-12DT.
QS0J65BTB2-12DT Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=QS0J65BTB2-12DT&select=5


...more relevant model market price >>>>