Total points: 20 points.
Input points: 12 points.
Output points: 8 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 75*75*90.
MITSUBISHI FX1S series PLC is suitable for the smallest package,
It is the preferred target for low cost users to seek powerful control over a limited range of I/0 .
FX1S provides up to 30 I/O points, and can be transmitted through serial communication data,
MT models also have the ability to locate, widely used in a variety of small mechanical equipment
QY82P Output points: 8 points.
Output voltage and current: DC12/24V.
Output response time: 2ms.
8 point /1 a public side.
Output form: transistor output, leakage type.
24 point terminal station QY82P.
MITSUBISHI PLC protection and chain procedures .
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system QY82P.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Fiber length: 50 meters.
SSCNET III cable (long distance optical fiber, high bending life).
Joints for CN1A and CN1B. The analog input adapter (FX3U- - racy -BD)CPU:A2SHCPU PLC is the same.
PLC program capacity: 30K step.
I/O points: 1024 points.
Processing speed (sequential order): 0.25 s/ step.
Control axis: up to 8.
Servo program capacity: 13K step.
Servo amplifier: SSCNET connected external servo amplifier.
PLC programming has a wide range of applications, powerful, easy to use, has become one of the main devices of modern industrial automation,
In all areas of industrial production has been widely used,
Applications in other areas (such as civil and home automation) have also been rapidly developed.
It uses programmable memory,
An instruction used to perform logical operations, sequence control, timing, counting and arithmetic operations in its internal storage,
And through digital, analog input and output,
Control of various types of machinery or production processes. Prograammable controller and related equipment,
Should be easy to make the industrial control system to form a whole, easy to expand the principle design of its functions QY82P.
As can be seen from the above definition, PLC is a program to change the control function of the industrial conttrool computer,
In addition to the completion of a wide variety of control functions, as well as with other computer communications networking features QY82P.
QY82P Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=QY82P&select=5