Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals .
A Safety Measure for Hazardous Operations ZX1-LD100A61 2M.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines
ZX1-LD100A61 2M
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices ZX1-LD100A61 2M.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors .
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4). Thermocouple type: J (IC) ZX1-LD100A61 2M.
Heat resistance: heat resistant.
External: all glass fiber outer foreskin .
Compensating wire length: 8 M.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a thermostat.
According to the temperature, place, the surrounding environment to be measured.
Products with various shapes, shapes, lengths and terminals.
Appearance: Standard.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: NPN output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series inncludes models that eenable switching between,
dark-ON and light-ON operation ZX1-LD100A61 2M.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for ddarrk-ON,
operation are also available ZX1-LD100A61 2M.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature.
ZX1-LD100A61 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=ZX1-LD100A61 2M&select=5