Appearance: Round/Flat without Voltage Reduction Unit M22-F.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Round Indicator Series with 22 dia. and.
25 dia. (when using a ring).
Same type as the A22-series Pushbutton Switches .
Use 25-dia. ring to install in 25-dia E2B-M12LS04-WZ-C2 2M. panel cutouts.
IP65. Actuator type: Roller plunger.
Compact Vertical Models Sized for Asian
E2B-M12LS04-WZ-C2 2M
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring.
RoHS complaint.
Degree of protection: IP65 E2B-M12LS04-WZ-C2 2M. Size: M8, Non-shielded.
Sensing distance: 4 . 0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 27 (39).
Output configuration: PNP.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated E2B-M12LS04-WZ-C2 2M.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) .
Modular construction simplifies customization. Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Sensing distance: 3 m (150 mm).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Relay output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog iinput: ±0 E2B-M12LS04-WZ-C2 2M.2% FS (previous models: ±0 .5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannuaal, RUN/STOP, and alarms) and the PV or SV E2B-M12LS04-WZ-C2 2M.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
E2B-M12LS04-WZ-C2 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2B-M12LS04-WZ-C2 2M&select=5