Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.130 A; 60 Hz, 0.100 A .
Rated input: 50 Hz, 12 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 1700 r/min; 60 Hz, 2000 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1 . 5 m3/min.
Maximum static pressure: 50 Hz, 19 E2FM-X2B2 2M. 6 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 34 dB
E2FM-X2B2 2M
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series E2FM-X2B2 2M.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor) E2FM-X2B2 2M.
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 150 s.
Rated voltage: 24 VDC.
Terminal block type: Spring-cage terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set.
-Two logical AND connection inputs. Model: C200H-ID216.
No. of points: 64 pts.
Specifications: 24VDC.
Weight: 180g max.The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventivve maintenance function is increased,
Further performance improvement E2FM-X2B2 2M.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV E2FM-X2B2 2M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
E2FM-X2B2 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2FM-X2B2 2M&select=5