Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Reverse hinge lever .
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types E3JK-TP11-L 2M.
A series of standard models for micro loads is available
E3JK-TP11-L 2M
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Function: Phase sequence, phase loss, and temperature monitoring.
Power supply voltage: 100 to 240 VAC.
Monitor Temperature Rise through E3JK-TP11-L 2M.
Internal Motor Loss.
Temperature, phase sequence, and phase loss monitoring with,
the DIN 22 . 5-mm-sized K8AK-PT Relays.
Side-by-side mounting of K8AK-PT Relays.
Specially designed for internal motor monitoring; no setting required.
Test/Reset Button for confirmation of output operation.
Monitoring also performed for thermistor disconnections and short circuits.
Manual or automatic resetting with the same Relay E3JK-TP11-L 2M. Product name: E@@S type CPU Units with 14 I/O Points .
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8;Outputs, 6;
Output type, Relay; Program capacity, 2K steps; memory Data capacity, 2K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.16A; 24 V,0.07A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3JK-TP11-L 2M.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput E3JK-TP11-L 2M.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
E3JK-TP11-L 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E3JK-TP11-L 2M&select=5