Static type reverse electric relay K2FW type.
Ensure high accuracy digital UFR/OFR.
Constitute by the crystal oscillator plus digital IC,
Can achieve high accuracy of frequency detection (adjustment, detection accuracy of less than 0.1HZ).
50-60HZ share, can be adjusted arbitrarily in the range of 45-65HZ through the surface of the dial switch plate E3JK-TR13-D 2M.
Because of the high speed detection, the low frequency relay can detect the system accident before the under voltage relay
E3JK-TR13-D 2M Name: Laser Reflectors, Sheets.
Ambient operating temperature range: -10 to 55°C (No icing).
Ambient storage temperature range: -25 to 70°C (No icing).
Ambient operating humidity range: 35 to 85% (No condensation) E3JK-TR13-D 2M.
Ambient storage humidity range: 35 to 85% (No condensation) . Actuator: Plunger.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available E3JK-TR13-D 2M. )
M12-connector models are also available, saving on labor and,
simplifying replacement .
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: 1C contact type.
Shape: square.
Terminal shape: terminal for printed board.
Action: alternate.
Display mode: LED display.
Operation Department color: red.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thhe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3JK-TR13-D 2M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation E3JK-TR13-D 2M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.