A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required.
No PC card is provided with the Unit.Appearance: 40-dia. head Push-lock Turn-reset without Voltage Reduction Unit A22E.
Operating: Contact configuration, 2NC (1NC + 1NC); Lighting, LED; Rated voltage, 24 VAC/VDC .
Push-lock turn-reset system E52-P20AY D=3.2 NETU 2M.
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout
E52-P20AY D=3.2 NETU 2M
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts) E52-P20AY D=3.2 NETU 2M.
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated E52-P20AY D=3.2 NETU 2M. Input type: NPN/ voltage pulse input type .
Event input terminal 5 points (HOLD, RESET, COMPENSATION) is equipped with.
External power supply DC12V80mA.
Linearity: voltage; NPN open collector (OUT5, OUT4, OUT3, OUT2, OUT1).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
High speed pulse.
Measuring, increasing or decreasing pulse meter.
Action determine the color, can switch the green / Red 2 kinds of color display.
The best choice of rotating encoder and all kinds of ON/OFF pulse signal at high speed,
The cumulative pulse input is 50kHz, the phase difference pulse is 25kHz, and the increase or decrease of pulse is 3Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display ffunction, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E52-P20AY D=3.2 NETU 2M.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput E52-P20AY D=3.2 NETU 2M.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
E52-P20AY D=3.2 NETU 2M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E52-P20AY D=3.2 NETU 2M&select=5