Actuator: Hinge roller lever.
Economical, High Utility Enclosed Switch.
Enclosed Switches with Built-in Basic Switches for High,
Repeatability and Durability of 10 Million Operations Minimum.
Panel mount versions have the same operating position as,
Z Basic Switch.
Suitable for applications demanding higher mechanical,
strength, dustproof and drip-proof properties than those,
on basic switches
F03-16SF-100M
Resin molded terminal versions are available.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.). Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling F03-16SF-100M.
No. of auxiliary outputs: 1 .
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-R1TC;
Resistance thermometer input, E5GN-R1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function F03-16SF-100M.
Indication Accuracy .
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD003(3G2A5-AD003).
Input: 2 pts.
Specification: 0~+5V.Open circuit: voltage, no voltage, DC circuit breaker.
Appearance: R2 shell, also has F4 shell.
Rated current: AC110V.
Rated frequency: 50/60Hz.
Consume VA: action time 10VA below (except for reactor part).
Action current adjustment range (zero phase converter primary current):
0.1-0.2-0.3-0.4-0.6A (5 shunt).
Control output: -.
Relay control output for switching circuit breakers: power through capacity, C110V/10A;
Switch capacity: AC110V/10A (COS =1).
Quality: about 2kg.
External: Mount Searl N1.5.
High voltage grounding relay AGF type, anti wave interference,
Arc grouunding, short circuit ccapability, high reliability F03-16SF-100M.
The anti - interference ability is strong, and can safely correspond to the arc grounding fault.
The grounding relay and the zero phase converter ZCT can be separately used.
(any combination is not more than JIS of thee sspecified error range, and therefore can be used)
Can carry out fine current adjustment, easy to coordinate F03-16SF-100M.
In all the models set up alarm terminal.
F03-16SF-100M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F03-16SF-100M&select=5