Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @ F2EL-X2MF1-M1.
Conduit size (See Note.): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock
F2EL-X2MF1-M1
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices F2EL-X2MF1-M1.
(4-, 5-, and 6-contact models are available) .
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames F2EL-X2MF1-M1.
The plastic material makes the Slide Key suitable,
for lightweight doors . Actuator: Bevel plunger.
Type: Limit.
Operation Indicator: Provided.
Repeat accuracy: 3 µm max.
Operating force OF max: 3.92 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 5 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes.
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E:: Interval, F: Cumulatiive,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 F2EL-X2MF1-M1.
External connections: 11-pin socket.
Input: Signal, Reset, Gate (NNPN/PNP input) F2EL-X2MF1-M1.
Output: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.
F2EL-X2MF1-M1 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=F2EL-X2MF1-M1&select=5