Product: DeviceNet Unit.
Specifications: For CS Series,
Functions as either a master or a slave.
2,048 I/O points.
Standards: UC1, N, L, CE.
A DeviceNet Unit for the CS Series.
That Boasts Industry-leading.
Performance and Functions. Type: Conforming to auxiliary power relay specifications.
Contact form: 4PDT .
Cased: Plug-in (octal pins)terminals F39-LR1.
Stable Contact Reliability and Long Life
F39-LR1
Easy to mount, wire, and use.
A large selection of models including various contact forms,
DC-switching models, and open models.
Mechanical life: 5,000,000 operations; electrical life,
(under rated load): 500,000 operations.
Models also available with built-in diodes and for use as,
auxiliary power relays F39-LR1. Sensing method: Through-beam (Emitter + Receiver).
Connection method: Standard M8 connector.
Sensing distance: 10 m.
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models F39-LR1.
Mechanical axis and optical axis offset of less than ±2 . 5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically aalternate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV F39-LR1.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs F39-LR1.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F39-LR1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F39-LR1&select=5