Power supply voltage: 5 to 24 VDC.
Output configuration: Open-collector output.
Resolution (pulses/rotation): 300, 360, 500, 600, 720, 800, 1,000, 1,024;
1,200, 1,500, 1,800, 2,000, 2,048; 2,500, 3,600.
Hollow-shaft Encoder.
Incremental model.
External diameter of 40 mm.
Resolution of up to 3,600 ppr .
Slim design at only 26 mm thick F3SJ-A0479N14. Contact form: SPST-NO/SPST-NC.
Type: Standard Models.
Rated voltage: AC: 24, 100, 110, 120, 200, 220, 230, 240;
DC: 12, 24, 48, 110, 220
F3SJ-A0479N14
MK-S-series Relays with DC-switching,
Models That Can Switch 220 VDC, 10 A,
(Resistive Load).
Switch a DC load of 220 VDC, 10 A (resistive load).
Models for AC Loads can switch 250 VAC, 15 A (resistive load) F3SJ-A0479N14.
Lineup includes models with SPST-NO and SPST-NO/SPST,
NC contact forms .
Using a SPST-NO/SPST-NC contact form enables detecting,
contact welding. (When the NO contacts become welded, the,
NC contacts will maintain a minimum distance of 0.5 mm.).
Models available with operation indicators and built-in test buttons.
RoHS compliant.
Standards: UL, IEC (TÜV certification) F3SJ-A0479N14. Terminal type: Exposed-lead Models .
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see tthe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV F3SJ-A0479N14.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation F3SJ-A0479N14.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
F3SJ-A0479N14 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SJ-A0479N14&select=5