Control power supply voltage: 200/220 VAC.
Input: DC, Input voltage range, 0.2 to 12 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) .
Detect three-phase AC current for under and/or overcur,
rent using current converter
F3SJ-A0770P55
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection F3SJ-A0770P55.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F) .
LED operation indicator.
UL/CSA approval (SDV-F@). Socket body.
Representative examples of applicable models.
General relay: G2R-_-S series; G2R-2-S.
Timer: H3RN series; H3RN-2-B.
Liquid leakage detector: K7L series; K7L-_B.
Pole number: 2.
Socket for MY relay, G2R-S relay.
Save hours of Push-InPlus terminal type to add product series F3SJ-A0770P55.
Using Plus Push-In terminal, compared with the previous screw terminals,
Save wiring time (compared with the previous screw terminals, can shorten the wiring time of about 60%*) .
Screw will not loose, to achieve maintenance free.
The insertion force is small, the drawing strength is big, and the wiring time is saved, and the high reliability is simultaneously considered.
When connecting multiple strands, the use of non - holding mechanism,
Insert a word screwdriver to keep it.
2 wires can be inserted in each terminal.
DIN guide rail installation, screw mounting common. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Center roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulatiing material F3SJ-A0770P55.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfiirmation of operation F3SJ-A0770P55.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
F3SJ-A0770P55 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SJ-A0770P55&select=5