Unit type: CS1 Special analog I/O Units.
Product name: Analog I/O Units.
Specifications: I/O points,
4 inputs, 4 outputs;
Signal range selection,
Set separately for each input;
Signal range, 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 V to 10 V, 4 to 20 mA;
Resolution, 1/4000 ;
Conversion speed, 1 s/point .
Externa connection, Removable erminal block F3SN-A1672P25-02TS.
Current consumption: 5V, 0.20A; 26V, 0.20A
F3SN-A1672P25-02TS
Standards: UC1, N, L, CE.
For Various Analog I/Os.
Analog Input Units for converting,
analog input signals into binary data.
Analog Output Units for converting ,
binary data into analog output signals. Detection mode: diffuse reflection type F3SN-A1672P25-02TS.
Detection range: 100mm.
Purpose: small,
Small thin space probe;
Interference prevention function with close installation3-position Enabling Switch for Safer .
Robot Operation.
Clicking feel.
Conforms to U.S. standards (ANSI/RIA R15.06-1999) for.
3-position switches.
Can be mounted in two directions. E3F3-R61 detection methods: Regression reflection type,
Wire lead out type,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyClassification: Standard F3SN-A1672P25-02TS.
Contact gap: G (0.5 mm).
Drip-proof terminal protective cover: Not provided.
Actuator: Reverse hinge lever.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,,
3NC contact forms F3SN-A1672P25-02TS.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads F3SN-A1672P25-02TS.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
F3SN-A1672P25-02TS Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SN-A1672P25-02TS&select=5