Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply .
One SPDT output relay, 5 A at 250 VAC (resistive load) F3SN-A1777P25-01.
World-wide power specifications supported by one Unit (switchable)
F3SN-A1777P25-01
Relay status can be monitored using LED indicator. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.085 A; 60 Hz, 0 F3SN-A1777P25-01. 075 A .
Rated input: 50 Hz, 12 W; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 2800 r/min; 60 Hz, 3300 r/min.
Maximum flow rate: 50 Hz, 0.80 m3/min; 60 Hz, 0.90 m3/min.
Maximum static pressure: 50 Hz, 42 Pa; 60 Hz, 58 Pa.
Noise: 50 Hz, 37 dB; 60 Hz, 40 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment F3SN-A1777P25-01.
Shaft supported by ball bearings for highly-reliable operation .
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Control output: Time-limit SPDT and Instantaneous SPDT.
Supply voltage: 220 VAC (50/60 Hz).
Solid-state Timer with Single Time Range.
and Operating Mode.
Time range: H3BA-X8HA (0.05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h).
Operating mode: ON-delay only.
Pin type: 8-pin only. Input/Output: Outputs.
Internal I/O circuit common: PNP (+ common).
I/O points: 4 points.
I/O connection method: Sensor connector.
Rated voltage for I/O power supply: 24 VDC.
Eight Waterproof Terminal Models.
Emphasizing Cost Efficiency.
Reduced Labor.
Connection using connectors reduces the lead time,
required for installation. No tools are required for,
connection to a variety of devices.
Reduced Wiring.
Signal line wiring has been reduced so that the,
Terminal can be mounted closer to sensors and,
other devices.
Relay Box not Required.
Environment--resistant, dust-tigght, drip-proof,
construction (IP67) enables direct on-site,
mounting F3SN-A1777P25-01.
Easier Maintenance.
Significant reductions not only in setup time but also,
maintenance time.
Reduced Space, Improved Operability,
Compact design (160 x 54 mm (W x H)) (88-ppoint models) F3SN-A1777P25-01.
Settings and connections can be performed using,
the switch and connectors on the front side of the Terminal.
System Configuration.
F3SN-A1777P25-01 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SN-A1777P25-01&select=5