Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: AC type.
Shape: non shield.
Detection range: 30mm.
Action mode: NO/NC (toggle). Rated voltage: 115 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage F3SN-A1822P25.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min
F3SN-A1822P25
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 86 Pa; 60 Hz, 48 Pa.
Noise: 50 Hz, 55 dB; 60 Hz, 56 dB.
Weight: Approx. 2220 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting F3SN-A1822P25.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades F3SN-A1822P25. Miniature Basic Switch that,
Offers High Reliability and.
Security.
Wide variation of best-selling microswitches with,
switching currents of 10 to 21 A.
Can be used for interrupting current when doors,
are opened or closed.
Available in two types of cases: thermoplastic resin,
and thermosetting resin. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-R1TC;
Resistance thermometer input, E5GN-R1P.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternaate,
between displayinng the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV F3SN-A1822P25.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs F3SN-A1822P25.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
F3SN-A1822P25 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SN-A1822P25&select=5