Appearance: Key-type Selector Switch A22K.
Number of notches: 3 notches.
Reset method: Manual.
Output: SPST-NO + SPST-NC.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Socket Unit.
Finger protection mechanism on Switch Unit provided as a standard feature .
Use 25-dia. ring to install in 25-dia F3ZN-S0450N15. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round type) crimp terminals
F3ZN-S0450N15
IP65 oil resistance. Applicable CPU Units: CQM1H-CPU51/61.
Mounting locations and number of Boards: 1 Board can be mounted in either slot 1 or slot 2.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 60 g max F3ZN-S0450N15. Control supply voltage: 110/220 VAC; With voltage fluctuation compensation .
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out F3ZN-S0450N15.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see tthe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV F3ZN-S0450N15.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation F3ZN-S0450N15.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
F3ZN-S0450N15 Operation manual / Instructions / Catalog download link: