Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 90 A at 200 to 480 VAC (See note 2.).
Rated input voltage: 100 to 240 VAC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series F3ZN-S1125P15.
All models feature the same compact dimensions to provide a,
uniform mounting pitch
F3ZN-S1125P15
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV F3ZN-S1125P15.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)) . Type: 1a1b welding terminal.
Shape: round.
Type: General load.
Motor function: alternate action (self retaining).
With lamp: no light.
Operation Department color: black.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good F3ZN-S1125P15. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0 . 4 A).
Operation: Alternate operation (Self-holding).
Output: DPDT.
Lighting: LED, 24 VDC.
Operation Unit color symbol: Enter the desired color symbol for the,
Pushbutton in @@. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Power supply voltage: 100 to 240 VAC.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater controll methods,
including OON/OFF control, phase control, and cyclic control F3ZN-S1125P15.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads F3ZN-S1125P15.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
F3ZN-S1125P15 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3ZN-S1125P15&select=5