Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No.
Control output: Contact (SPST-NO) .
Operating mode: Reversible counting, individual inpu F3ZN-S1440N60.
Max.counting speed: 30 cps
F3ZN-S1440N60
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter F3ZN-S1440N60.
Power supply freely selectable within a range of 100 to 240 VAC .
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Panel mount plunger; Medium OP.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety F3ZN-S1440N60.
A large switching capacity of 15 A with high repeat accuracy .
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection distance: infrared 100mm.
Output mode: PNP output. Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OOFF Delay, E: Interval,, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 F3ZN-S1440N60.
External connections: Screw terminals.
Input: Signall, Reset, Gate (NPN/PNP input) F3ZN-S1440N60.
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.
F3ZN-S1440N60 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3ZN-S1440N60&select=5