Temperature range: 40 to 90.
Digital thermometer for replacing alcohol thermometer.
With the aid of microcomputer, high precision can be realized (with 0.1 degree C as the unit).
Built in battery, no power supply connection.
Large LCD (character height 12mm) digital display. Terminal type: Exposed-lead Models .
Protective tubing diameter D (mm): 6 FL-XBK1. 4 dia. .
Protective tubing length L: 20cm.
Lead wire type: Heat resistive
FL-XBK1
Lead wire length M : 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers FL-XBK1.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal . Rated voltage: 100 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.140 A; 60 Hz, 0.115 A .
Rated input: 50 Hz, 10 W ; 60 Hz, 9 W FL-XBK1.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3200 r/min .
Maximum flow rate: 50 Hz, 0.8 m3/min; 60 Hz, 0.9 m3/min.
Maximum static pressure: 50 Hz, 42.1 Pa; 60 Hz, 58.8 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Economical, Compact, High-performance,
DIN 48 × 48-mm Ground Fault Relay for Low,
Voltages.
Performs continuous monitoring and detection of ground faults,
in low-volltage circuits due to the detterioration of insulation in,
electrical devices FL-XBK1.
Higher reliability ensured with improved resistance to high-fre,
quency noise when used for inverter loads.
Ground Fault Relays and through-type ZCTs (zero-phase current,
transformers) are mutuuallly compatible FL-XBK1.
The through-type ZCTs are equipped with test terminals,
allowing operation tests for Ground Fault Relays to be performed withease.
FL-XBK1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FL-XBK1&select=5