Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 20 A at 24 to 240 VAC.
Rated input voltage: 5 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track .
Close mounting possible for linking terminals FLV-DD150R.
(Except for G3PA-260B-VD and G3PA-450B-VD-2
FLV-DD150R)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). The main body: terminal type, temperature input type FLV-DD150R.
Category: control output 1 point type (power supply AC100 ~ 240V) .
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: - FLV-DD150R.
Transfer output: -.
Communication: RS-485 .
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Appearance: Round/Full-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-G.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring) FLV-DD150R.
Lever for easily mounting and removing the Switch Unit .
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounteed using either open-type (fork-type) or closed-type FLV-DD150R.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).